We have created a awesome theme
Far far away,behind the word mountains, far from the countries

PRODUCT > IR-80-H

IR-80-H

IR-80-H

IR-80-H

Features
IR-80-H non-contact infrared thermometer measures the infrared wavelength emitted from the target and converts it to standard current signal output (4~20mA) and RS-485 communication signal output.
It can measure from 500¡É to maximum 1700¡É in the distance of 80:1 D:S (Distance to Spot).
Emissivity is 0.10 ~ 0.99 adjustable. Two built-in laser pointers can aim at the target.
Ordering information
Code Number IR-80-H-¡à-¡à-¡à
Ordering information
MODEL Description
Code A Temperature Range
1 150~700¡É
2 500~1800¡É
3 800~2200¡É (Silicon sensor)
Z Other
Code B Output
M DC 0~20 mA
N DC 4~20 mA
V Voltage Output (DC 1~5V)
Z Other
Code C Cable Length
1 3m
Z Other
Accessory
Accessory
Name Shape Usage Remark
Fixing nut ºÎÂø¿ë ³ÊÆ® Sensor fixing nut Basic accessory
Mounting bracket °íÁ¤ ºê¶óÄÏ Sensor mouning bracket Option
Specification
Specification
Range 150~700¡É 500~1700¡É
Device InGaAs, Silicon
Accuracy ¡¾1¡É/F.S or 1¡É
Error Range ¡¾1%
Field of view(D:S) 80:1
Wavelength Rang 1~1.6§­, 2.6§­, 0.85~1.1§­
Response Time Within 0.1sec
Emissivity (one color) 0.10~0.99
Analog output 4~20mA, 1~5V(option)
Communication output RS-485 Communication
Power DC 16~24V (Max 50mA)
Operating Temperature 0~70¡É
Resolvable Temperature 0.1¡É
Operating Relative Humidity 5~90%
Storage Temperature -30~85¡É
Waterproof 630~670nm(red)
Size 51 x 161(L)
Casing material Aluminum Alloy
Weight 600g
Cable length 3M, other